Mitsubishi FX2N-232-BD PLC Connect Communication Board FX2N232BD
- Extended Product Type: FX-series
- Product ID: FX2N-232-BD
- Mitsubishi Type Designation: FX-series
Description: FX2N-232-BD Mitsubishi RS232 Communication Board
Features Mitsubishi PLC Connect Communication Board FX2N-232-BD/FX2N232BD
Multi-point 8-Channel Analog Input
- A single block is capable of handling the input of 8 analog channels. Voltage, current and temperature (thermocouple) inputs
can be selected for each channel. (Mixed settings possible.)
High Functionality
- Highly precise setting variations such as 0.63mV for voltage input, 2.50µA current input and 0.1°C temperature input enable minute detection of fluctuation in analog input values.
High-Speed A/D Conversion
- Conversion is executed at 500µs times the number of channels (temperature input: 3ms×number of channels). Most efficient
when average analog input data is used.
Specification of Mitsubishi PLC Connect Communication Board FX2N-232-BD/FX2N232BD
| Ambient temperature | ||
| Ambient humidity | ||
| Vibration resistance | Installed on DIN rail | Frequency: 10 to 57 Hz |
| Frequency: 57 to 150 Hz | ||
| Direct installing | Frequency: 10 to 57 Hz | |
| Frequency: 57 to 150 Hz | ||
| Shock resistance | ||
| Noise resistance | ||
| Dielectric withstand voltage | ||
| Insulation resistance | ||
| Working atmosphere | ||
| Working altitude | ||
|
0 to 55°C (32 to 131°F) when operating and -20 to 70°C (-4 to 158°F) when stored
|
|
35 to 85%RH (no condensation) when operating
|
|
Half amplitude: 0.035 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)
|
|
Acceleration: 4.9 m/s2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)
|
|
Half amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)
|
|
Acceleration: 9.8 m/s2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)
|
|
147 m/s2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z
|
|
By noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz
|
|
Non-isolated between communication line and PLC main unit (Do not perform a withstand voltage test.)
|
|
Non-isolated between communication line and PLC main unit (Do not perform an insulation resistance test.)
|
|
Free from corrosive or flammable gas and excessive conductive dusts
|
|
2000 m or less
The PLC cannot be used at a pressure higher than the atmospheric pressure to avoid damage. |