Automation Pioneer

Rosemount 3051CD2A22A1AM5 Differential Pressure Transmitter

$5,800.00

AVAILABILITY: Generally allow 7-10 days to ship

SKU: 3051CD2A22A1AM5 Category: Tag: Brand:

Rosemount 3051CD2A22A1AM5 Differential Pressure Transmitter

  • Product Name: Rosemount 3051CD2A22A1AM5 Differential Pressure Transmitter
  • Full Model Code: 3051CD2A22A1AM5
  • Manufacturer: Emerson (Rosemount)

Rosemount 3051CD2A22A1AM5 Coplanar Pressure Transmitters are the industry standard for differential, gage, and absolute pressure measurement. The coplanar platform enables seamless integration with manifolds, flow, and level solutions.
■ Loop Integrity and Plugged Impulse Line Diagnostics detect issues that might compromise the integrity of the output signal (code DA1).
■ Bluetooth connectivity enables efficient, reliable, and safe configuration and maintenance (code BLE).
■ Back-lit graphical display with local language capability (code M6).
■ Safety certification and proof testing (code QT and T9)

Applicable Standards & Certifications for Rosemount 3051CD2A22A1AM5 Pressure Transmitter

The transmitter shall conform to the following international standards as applicable:

  • Functional Safety: SIL2 capable per IEC 61508 (when configured with appropriate options)
  • EMC/EMI: IEC 61326, EN 61326
  • Hazardous Area Approvals: ATEX, IECEx, FM, CSA (specify where required)
  • Pressure Equipment Directive (PED)
  • Environmental Protection: IP66/67, NEMA 4X
  • Quality: Manufacturer ISO 9001 certified
  • Calibration Standards: Traceable to national standards (e.g., NIST)

GENERAL REQUIREMENTS

The pressure transmitter shall:

  • Be designed for continuous industrial process service
  • Provide high reliability, long-term stability, low drift, and advanced diagnostics
  • Be compatible with HART® communication protocol (standard)
  • Be loop powered (2-wire, 4-20 mA) unless another protocol is specified

PERFORMANCE SPECIFICATIONS for Rosemount 3051CD2A22A1AM5 Pressure Transmitter

Pressure Types

Transmitter shall measure:

  • Gauge Pressure (PG)
  • Absolute Pressure (PA) — where certified reference vacuum is provided
  • Differential Pressure (PD) — if differential model is specified

Measurement Ranges

Provide ranges (select as required):

  • Gauge/Absolute: 0–15 psi to 0–10,000 psi (or equivalent metric units)
  • Differential (if applicable): 0–5 inH₂O to 0–250 inH₂O (or equivalent)

Accuracy

Transmitter shall have the following minimum performance:

  • Total Accuracy: ±0.04% of span (including linearity, hysteresis, and repeatability)
  • Optional Enhanced Accuracy: ±0.025% of span

Temperature Limits

  • Operating Ambient: –40°C to +85°C (–40°F to +185°F)
  • Process Temperature: –40°C to +105°C (–40°F to +221°F)
  • Storage Temperature: –40°C to +100°C (–40°F to +212°F)

Long-Term Stability

  • Typical drift: ≤±0.1% of URL per year

Overpressure

  • Shall withstand at least 2× full scale pressure without degradation (unless otherwise specified)

SENSOR & WETTED PARTS MATERIAL

  • Wetted materials shall be corrosion resistant; 316L stainless steel minimum
  • Optional alloys: Hastelloy, Monel, or others as required by process fluid compatibility
  • Sealing materials compatible with process fluid

OUTPUT & COMMUNICATION

Analog Output

  • Standard: 4–20 mA, two-wire, HART® digital communication superimposed
  • Optional: Foundation Fieldbus or PROFIBUS PA (if specified)

Digital Communication

  • HART® version (specify if a specific version is required)
  • Configuration, calibration, and diagnostics accessible via host system or handheld communicator

Power Requirements

  • 12–42 V DC loop supply (typical)
  • Power consumption shall not exceed specified limits for selected protocol

HOUSING & MOUNTING

Enclosure

  • Rugged, corrosion-resistant housing (aluminum or stainless steel per project requirements)
  • Environmental protection rating: IP66/67, NEMA 4X

Display & Local Interface

  • Optional local LCD display with configurable units, status, and diagnostics

Mounting

  • Options for direct, pipe, or remote mounting as specified

DIAGNOSTICS & FEATURES

The transmitter shall provide:

  • Self-diagnostic functions including sensor health, over-range/under-range warnings
  • Zero and span drift compensation
  • Auto-trim calibration functions
  • Programmable failsafe and alarm limits

CALIBRATION & TESTING

Each unit shall be:

  • Factory calibrated to specified range(s)
  • Tested for zero and span accuracy
  • Pressure tested at rated pressure levels
  • Supplied with a calibration certificate traceable to national standards

DOCUMENTATION

Supplier shall provide in English:

  • Manufacturer’s datasheets
  • Installation, operation and maintenance manual
  • Calibration certificate
  • Hazardous area certificates (if applicable)
  • Configuration and loop wiring diagrams

INSTALLATION & COMMISSIONING

Supplier shall:

  • Provide installation instructions and best-practice guidelines
  • Assist with startup/configuration as required
  • Verify loop integrity with host or DCS

WARRANTY & SUPPORT

  • Manufacturer’s minimum warranty of 12 months from commissioning (or 18 months from shipment)
  • Technical support via phone/electronic channels
  • Availability of spare parts and calibration services

QUALITY ASSURANCE

  • Supplier shall be ISO 9001 certified
  • Products shall comply with project quality plan requirements
  • Inspection and test records shall be provided upon request

OPTIONAL FEATURES 

  • Dual 4–20 mA outputs
  • Redundant sensors
  • High-temperature process seals
  • SIL diagnostic equipment package
  • Remote electronics housing with extended temperature range
Weight 26 lbs
Dimensions 18 × 16 × 24 in

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Scroll to Top